GDC MTA Carrier # Curved (0.8Mm) Mta4869

Brand: GDC
Availability:

10 in stock


ENDO GUNS FOR RETROGRADS APPLICATIONS SYRINGES

$29.88 $43.13

10 in stock

They are manufactured from selective stainless steel by skilled
workers with modern machines, keeping control on production and quality at every step to guarantee a supply of Instruments
with utmost precision. MTA Carrier has been designed to dispense MTA at the designated site of operation, with ease of handling. Delivers MTA directly to the apex of the root canal Less time-consuming MTA being hydrophilic requires moisture to set, making absolute dryness contraindicated. The presence of moisture during the setting improves the flexural strength of the deity cement. Though moisture is needed for MTA to set, excess moisture results in a mix that is soupy and difficult to use. Therefore MTA carrier is useful in transporting the MTA at the site of operation.

SKU: GDC0026 Categories: , ,
  • Type: MTA carrier curved
  • Category: Endodontic
  • Material: Stainless Steel
  • Disposable / Reusable: Reusable

Packaging

  • 1 x GDC Mta Carrier # Curved (0.8Mm) Mta4869

Features

  • Made of high-grade Stainless Steel
  • Thin anatomic ends
  • Large handle – Better Operator fit
  • Rust Free
  • Autoclavable
  • Curved design for easy access and better placement

Directions to use

MAINTENANCE INSTRUCTIONS:
Must clean after every use with warm water to remove blood, tissues, and mucus from the instruments Ultrasonic cleaning is recommended for all the instruments specially articulated instruments such as forceps, rongeurs, etc
Use only standard and reputed brands of disinfectant solutions.
STERILIZATION:
We recommend that the temperature does not exceed 120C
Dry heat sterilization see that temperature does not exceed 180C and there should be no long exposure as this would cause discoloration,
loss of temper and this, in turn, would disturb the hardening of the instrument
Do not use substandard chemicals or disinfectants as they can damage the instruments. Avoid the use of unsuitable highly acidic chlorine-containing agents
Use Demineralized water only. Never rub an instrument with a metal brush at the time of cleaning.

FAQ

  • Is MTA Applicator sterilizable?

Yes, and it must be sterilized in dry heat or autoclave.
To avoid clogging, the applicator must be sterilized with its parts disconnected.