Waldent Electric Pulp Tester
- Pulp Vitality Tester
- Convienient to operate
- Preset speed mode (high-mid-low speed)
₹3300.00₹10000.00 (-67%)
Benefits
Brand warranty
Secure payments
upto 7 days returnable
Long expiry
EMI
Description
- Waldent Electric Pulp Tester It is a device to examine the vitality
of dental pulp using the electric stimulation The currrent used to stimulate the intradental nerves therefore creating a response. Studies were accompanied to measure the responses subjects by stimulating over the sensory threshold
to determine the vitality of tooth. It works in an efficient way
Electric Pulp Testing An Electric current can be applied to the tooth in order to generate an action potential in the type A delta fibres within pulp ; this elicit a
responses This test is conducted under a medium like toothpasteon dried tooth. - PLACEMENT:
- One end is placed on the tooth surface near the pulp horn
other end is placed on the lip
Asked for any tingling sensation
Specification
Additional information
Weight | 0.2 kg |
---|
Features
Features
-
- Preset speed mode (high-mid-low speed)
- Gentle , pulsed stimulus begins to increase at a rate of high -mid-low speed.
- Specifically designed for patient comfort (If patient indicates perception , simply release the button. The stimulus stoped immediately, but the numbers remain frozen on the screen for about 3mins
- Convienient to operate
Peak of stimulus current reaction numerical value.
- Between 0-40 , the patient feels ache and anesthesia , it means alive tooth nerve.
- Between 40-80 , with above mentioned reaction , if means part of tooth nerve dead.
- 80 , no above mentioned reaction dead tooth nerve.
Packaging
Packaging
- 2 x Test Electrode
- 1 x Cable Socket
- 1 x Light Indicator
- 1 x Battery
Warranty
Warranty
- Manufacturer/Importer warranty of 6 months as applicable for this product.
- Service and Warranty are handled by the manufacturer/importer directly for this product
- The Buyer acknowledges that the Products once sold will not be exchanged or taken back unless the seal of the package or the Product is intact or not altered in any manner or is not tampered as the case may be.
Directions To Use
Directions To Use
- Make the test wire link with the cable socket of the unit, afterwards insert the stainless steel hook and the test electrode into the interface of the unit.
- Strictly separate the tooth which will be measured from the saliva , blow the surface of the tooth until it is dry, so as to forbid the stimulation electric current to conduct from the gingiva or else there will appear a false stimulus current.
- Hang the stainless steel hook on any side of the mouth, then select different speed mode.
- Paste a spot of conducting glue or toothpaste on the contact interface (1/3 slide side) between test electrode and selected tooth. Then press the power switch.
- When the patient slightly feels toothache or anesthesia, You should take the test electrode away from the tooth and observe the figure on the screen in order to record it , this figure is the tooth’s stimulation current reaction number.