Unident Stainless Steel Autoclave Drum
Made up of Stainless steel Used to sterilize and store dressings materials (compresses, cotton, etc.), medical equipment and operating theatre linens and towels.
₹670.00
Benefits
Brand warranty
Secure payments
upto 7 days returnable
Long expiry
EMI
Description
Stainless Steel Autoclave Drum
COMPOSITION :
- Made up of Stainless Steel Sheet by deep draw process & confirm to IS specifications.
INDICATION :
- These are ideal for sterilization of Gauges, Dressing Cotton, Gloves, surgical instruments used in operation theatres and emergency wards.
Specification
Additional information
Weight | 0.1 kg |
---|---|
Brands |
Features
Features
- Flawless in concept, design & Finish.
- Lid Snaps fit on the body.
- Belt slots and perforations of the body correspond accurately.
- Custom designed chains for comfortable latching.
Packaging
Packaging
1 x Autoclave Drum
Direction to Use
Direction to Use
STEP 1:
- Place the Autoclave and sterilizing material on the table or on the shelf.
- Remove the stopcock whistle/valve from the vent tube fitted at the lid.
- Twist the lid of the autoclave Anticlockwise and lift the lid.
- Fill water in the base chamber.
STEP 2:
- Place the loaded Basket/Dressing Drum in the autoclave.
- Check that the rubber seal is in place and is in good condition.
- Put on the lid, press it down and turn it clockwise until it does not turn anymore.
- The sterilizer in the closed position will have both handles parallel and one above the other on either side of the stericlave.
STEP 3:
- Put and press down the Stopcock whistle/valve on the vent tube on the lid and turn on the power.
- After few minutes steam will start generating and at 15±2 lb psi pressure the steam will come out strongly from the stopcock.
- Let the process go on and after 15 minutes turn off the power and lift or pull out the Stopcock whistle/valve of the vent tube with forceps or piece of cloth.
- The whole steam will escape but it will be hot.
STEP 4:
- Make sure that there is no steam left in the sterilizer and pressure gauge is also at Zero lb psi.
- Now open the autoclave lid by twisting it anticlockwise and lift the lid off the base chamber.
- Remove the rack/dressing drum from the autoclave and Preserve them in a safe place.
STEP 5:
- Remove all the water from the base chamber and close the autoclave by putting the lid on it clockwise.
- Put the stopcock whistle/valve back on the vent tube for the next sterilization.