Waldent Obturation Pen System
- Down Pack Obturation System
- Double batteries to replace, convenient use
- Autoclavable Tips
₹9800.00₹25000.00 (-61%)
Benefits
Brand warranty
Secure payments
upto 7 days returnable
Long expiry
EMI
Description
- WALDENT OBTURATION PENWaldent Obturation Pen System is a Cordless system used for Warm Vertical Compaction while doing RCT. Using Obturation Pen, one applies pressure in a vertical direction to the heat softened gutta percha and thereby causes it to flow and to fill the entire lumen of the canal.FEATURES:– Slim design, light body, comfortable grip to reduce your exhaustion and easy handling.
– The needle type and temperature mode can be adjustable, make the gutta point more compact.
– Short heating time, up to 150 degree within 2s
– Adopting gutta percha vertical condensation technology
– Double batteries, convenient to replace, saving chairside timeFOR EFFECTIVE WARM VERTICAL COMPACTION:– A continuous tapering funnel should be present from the root canal orifice to the root apex.
– Root canal should be prepared so that it flows with the shape
– Shape of Apical foramen should not be changed or moved.
– Apical foramen should be kept as small as is practical so that excess gutta percha will not be forced through it during vertical compaction
Specification
Additional information
Weight | 1.5 kg |
---|---|
Brands |
Features
Features
1) Design
Simple design
Convenience in application
2) Tips
Four Tips – F, FM, M, ML
F: #45/02, FM: #50/04, M: #55/06, ML: #55/08
3) Time & Temperature
Needle type & temperature mode can be adjusted making the gutta percha point more contact
Short heating time, up to 150 degree within 2s
4) Technique
Vertical condensation technology
5) Charging
Double batteries to replace, convenient use
6) Disinfection
Autoclavable Tips
Packaging
Packaging
- 1 x Obturation Pen
- 1 x Charging Base
- 1 x Adaptor
- 2 x Batteries
- 4 x Tips (F, FM, M, ML)
Warranty
Warranty
- 6 months Warranty against the manufacturing defect on the equipment
- Other Accesories (like tips, etc) are not included in Warranty
- Service and Warranty are handled by the manufacturer/importer directly for this product
- The Buyer acknowledges that the Products once sold will not be exchanged or taken back unless the seal of the package or the Product is intact or not altered in any manner or is not tampered as the case may be.
Directions To Use
Directions To Use
STEP 1:
Preparation -gutta percha point
STEP 2:
Prepatration -hand plugger:
Prepare 2-3 plugger to compact gutta percha ,mark root canal length by rubber stopper.
STEP 3:
Preparation -pen tip:
Select proper pen tip for root canal
STEP 4:
Dry root canal:
Dry the root canal using paper point
STEP 5:
Select the gutta percha point.
STEP 6:
Mark the length of pen tip
STEP 7:
Insert gutta percha point:
Coat 3mm from the tip with sealer, insert in to root canal with pumping action
STEP 8:
Removal of excess gutta percha
Cut the excess gutta percha by pen tip.
STEP 9:
Heating & insertion:
Heat and insert pen tip with gutta percha to 4-6mm short of the working length
(NOTE: High temperature mode is recommended for this step because of too much gutta)
STEP 10:
Compaction:
Stop the heating and maintain the pressure about 10 secs
STEP 11:
Removal of pen tip:
Removal after heating the pen tip for 1~2 seconds to avoid gutta percha come out with pen tip
STEP 12:
Compact
Compact the warmed gutta percha with the plugger.
(NOTE: Its proper to use low temperature mode because of less gutta)
by Dr. Rakesh Sharma
The Waldent Obturation Pen System has greatly improved my endodontic practice. It’s easy to use, precise, and efficient. The temperature control and ergonomic design make it a game changer!
by Dr. Vinay
Satisfactory product at such low price. Double batteries to replace, convenient use.
by Dr. Dinesh
Fast Delivery. Needle type & temperature mode can be adjusted making the gutta percha point more contact